惠普服务器ssa找不到控制卡,月亮雨小组的天地 您所在的位置:网站首页 惠普p212阵列卡 惠普服务器ssa找不到控制卡,月亮雨小组的天地

惠普服务器ssa找不到控制卡,月亮雨小组的天地

2023-08-21 16:07| 来源: 网络整理| 查看: 265

[root@localhost:~] /opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show config    //显示所有配置和阵列卡

Dynamic Smart Array B140i in Slot 0b      ()

Port Name: 1I

Port Name: 2I

Array A (Solid State SATA, Unused Space: 0  MB)

logicaldrive 1 (894.20 GB, RAID 0, Failed)

physicaldrive 2I:0:5 (port 2I:box 0:bay 5, SATA SSD, 480 GB, OK)

physicaldrive 2I:0:6 (port 2I:box 0:bay 6, SATA SSD, 480 GB, OK)

Smart Array P440 in Slot 2                (sn: xxxxxxxxxxxxx)

Internal Drive Cage at Port 1I, Box 1, OK

Port Name: 1I

Array A (SATA, Unused Space: 0  MB)

logicaldrive 1 (7.28 TB, RAID 0, OK)

physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA HDD, 4 TB, OK)

physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA HDD, 4 TB, OK)

There are several helpful commands can be used:

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77# Show configuration

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show config

# Controller status

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show status

# Show detailed controller information for all controllers

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show detail

# Show detailed controller information for controller in slot 0

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 show detail

# Rescan for New Devices

/opt/smartstorageadmin/ssacli/bin/ssacli rescan

# Physical disk status

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd all show status

# Show detailed physical disk information

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd all show detail

# Logical disk status

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld all show status

# View Detailed Logical Drive Status

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 show

# Create New RAID 0 Logical Drive

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0

# Create New RAID 1 Logical Drive

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1

# Create New RAID 5 Logical Drive

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5

# Delete Logical Drive

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 delete

# Add New Physical Drive to Logical Volume

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7

# Add Spare Disks

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7

# Enable Drive Write Cache

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify dwc=enable

# Disable Drive Write Cache

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify dwc=disable

# Erase Physical Drive

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd 2I:1:6 modify erase

# Turn on Blink Physical Disk LED

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 modify led=on

# Turn off Blink Physical Disk LED

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 modify led=off

# Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify cacheratio=100/0

# Enable smart array write cache when no battery is present (No-Battery Write Cache option)

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify nbwc=enable

# Disable smart array cache for certain Logical Volume

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable

# Enable smart array cache for certain Logical Volume

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable

# Enable SSD Smart Path

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 array a modify ssdsmartpath=enable

# Disable SSD Smart Path

/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 array a modify ssdsmartpath=disable