惠普服务器ssa找不到控制卡,月亮雨小组的天地 | 您所在的位置:网站首页 › 惠普p212阵列卡 › 惠普服务器ssa找不到控制卡,月亮雨小组的天地 |
[root@localhost:~] /opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show config //显示所有配置和阵列卡 Dynamic Smart Array B140i in Slot 0b () Port Name: 1I Port Name: 2I Array A (Solid State SATA, Unused Space: 0 MB) logicaldrive 1 (894.20 GB, RAID 0, Failed) physicaldrive 2I:0:5 (port 2I:box 0:bay 5, SATA SSD, 480 GB, OK) physicaldrive 2I:0:6 (port 2I:box 0:bay 6, SATA SSD, 480 GB, OK) Smart Array P440 in Slot 2 (sn: xxxxxxxxxxxxx) Internal Drive Cage at Port 1I, Box 1, OK Port Name: 1I Array A (SATA, Unused Space: 0 MB) logicaldrive 1 (7.28 TB, RAID 0, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA HDD, 4 TB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA HDD, 4 TB, OK) There are several helpful commands can be used: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77# Show configuration /opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show config # Controller status /opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show status # Show detailed controller information for all controllers /opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show detail # Show detailed controller information for controller in slot 0 /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 show detail # Rescan for New Devices /opt/smartstorageadmin/ssacli/bin/ssacli rescan # Physical disk status /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd all show status # Show detailed physical disk information /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd all show detail # Logical disk status /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld all show status # View Detailed Logical Drive Status /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 show # Create New RAID 0 Logical Drive /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0 # Create New RAID 1 Logical Drive /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1 # Create New RAID 5 Logical Drive /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5 # Delete Logical Drive /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 delete # Add New Physical Drive to Logical Volume /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7 # Add Spare Disks /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7 # Enable Drive Write Cache /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify dwc=enable # Disable Drive Write Cache /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify dwc=disable # Erase Physical Drive /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd 2I:1:6 modify erase # Turn on Blink Physical Disk LED /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 modify led=on # Turn off Blink Physical Disk LED /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 modify led=off # Modify smart array cache read and write ratio (cacheratio=readratio/writeratio) /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify cacheratio=100/0 # Enable smart array write cache when no battery is present (No-Battery Write Cache option) /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify nbwc=enable # Disable smart array cache for certain Logical Volume /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable # Enable smart array cache for certain Logical Volume /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable # Enable SSD Smart Path /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 array a modify ssdsmartpath=enable # Disable SSD Smart Path /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 array a modify ssdsmartpath=disable |
CopyRight 2018-2019 实验室设备网 版权所有 |